Product description


EKM-25XDSE
Single Phase, Pass-Through kWh Meter, 2 or 3-Wire, 120V up to 120/240V, 100A, 60Hz
The 25XDSE has been designed to replace both of our legacy single phase pass-though kWh meters (EKM-25IDS and EKM-15IDS). This meter replaces the functionality of both of these legacy meters and offers a number of additional improvements to their designs.
Compact and very easy to install. Simple DIN-Rail Mounting. Wires pass through 13.7mm (0.5 inch) diameter tubes in the meter body — Will accept 22 AWG – 1 AWG wire. There are two piercing screws that pierce the wires that pass through the meter. The meter comes with two sets of bushings for medium and small wire diameter wires, which keep the wires centered so the piercing screws have no trouble engaging the conductor. The upside-down teardrop shape of the tubes also serves to keep the wires centered.
This meter only displays kWh on its LCD screen. The value always increments up and it is not re-settable. Unlike our Omnimeter series of kWh meters, this meter is not remotely readable.
Voltage: 120 volts 2-wire, 240 volts 2-wire, 120/240 volts 3-wireAmperage: Up to 100 ampsType: Pass-Through, Single-Phase, 60HzData: Pulse Output – 800 pulses per kWhModel: EKM-25XDSE
Installation Options

Single Phase 120/240V 3-Wire (2 hots, 1 neutral)
In this configuration both hot wires pass through the body of the meter. The piercing screws are used to pierce the wire insulation to provide the meter with a voltage reference for each line. There is also a port on the meter for a neutral reference. The meter will function without this connection (at ~1% accuracy) but it will be 0.5% accurate with the neutral connection.

Single Phase 120V or 208-240V 2-Wire (2 hots)
As described above, the meter is designed to meter single phase electrical systems that don’t have a neutral available. Both hot wires pass though the body of the meter and the piercing screws are used to pierce the wire insulation to provide voltage references to the meter.

Single Phase 120V or 208-240V 2-Wire (1 hot, 1 neutral)
In this case Line 1 passes though the tube marked L1. The piercing screw is used to pierce the wire insulation for L1 to provide the voltage reference to the meter. The Neutral reference can either pass through the Tube marked L2 or it can be connected to the port marked N. If the neutral passes though the L2 tube then the piercing screw is used to pierce the wire insulation for to provide the neutral reference to the meter.
Add to Cart
Add to Cart
Add to Cart
Customer Reviews
4.4 out of 5 stars 64
4.1 out of 5 stars 22
3.4 out of 5 stars 4
3.6 out of 5 stars 9
—
Price
$145.00$145.00
— no data
$276.00$276.00 $320.00$320.00
— no data
Single Phase
✓
✓
✓
✓
✓
Three Phase
no data
✓
✓
✓
✓
120V–240 2-Wire
✓
✓
✓
✓
✓
120/240V 3-Wire
✓
✓
✓
✓
✓
3-Phase 3-Wire Up To 415V
no data
✓
no data
✓
no data
3-Phase 4-Wire (with neutral) Up To 480V
no data
✓
no data
✓
no data
Remote Readable
no data
✓
✓
✓
✓
External Current Transformers
no data
✓
✓
✓
✓
3x Pulse Inputs (connect to water and gas meters)
no data
no data
no data
✓
✓
UL Listed (up to 240v)
no data
no data
✓
no data
✓
Single Phase 120/240V 3-Wire (2 hots, 1 neutral)
Single Phase 120V or 208-240V 2-Wire (1 hot, 1 neutral)
Single Phase 120V or 208-240V 2-Wire (2 hots)
Up to 100A and 13.5mm Wire Diameter (22 AWG – 1 AWG wire)
Read locally on the LCD display or remotely via pulse output